Orifice Flow Calculator
Orifice plate flow, bore sizing and pressure drop with step-by-step solutions
The Orifice Equation
An orifice plate creates a measurable pressure drop that maps to flow:
Symbols and SI units:
- тАФ volumetric flow, m┬│/s
- тАФ discharge coefficient, dimensionless; typically тАУ for a sharp-edged concentric plate
- тАФ velocity-of-approach factor, dimensionless
- тАФ orifice bore area, m┬▓; bore, pipe internal diameter, m
- тАФ differential pressure across the taps, pascals (Pa)
- тАФ fluid density, kg/m┬│
For free discharge from a tank under a head (m), and the equation reduces to .
The assumption people forget: the flow is treated as incompressible. For gases you must add the expansibility factor , and itself depends on Reynolds number, and tap arrangement.
Sizing, Pressure Loss and the Standard
Because , the relationship is strongly non-linear: halving the flow quarters the differential, which is why an orifice meter has a usable turndown of only about 3:1.
To size a bore, fix a target differential at maximum flow and solve for :
Keep within roughly тАУ; outside that band the coefficients are not well characterised.
The measured is not the permanent loss. Some pressure recovers downstream, and the unrecovered loss is roughly тАФ around of the differential at . That loss is a permanent pumping cost.
The rule that governs the real installation: a metering orifice must be designed and installed to ISO 5167 (or an equivalent standard such as AGA 3 for gas), which fixes the plate geometry, tap positions, straight-run lengths and the correlation. The hand calculation here shows the method; it is not a substitute for the standard.
Common Mistakes to Avoid
- Dropping the velocity-of-approach factor тАФ at , , and it grows quickly for larger .
- Mixing pressure units тАФ must be in pascals. kPa is Pa; a bar is Pa.
- Assuming flow is proportional to тАФ it goes with the square root, so a differential-pressure transmitter output must be square-rooted before it means flow.
- Treating the measured differential as the permanent loss тАФ much of it recovers downstream.
- Using a liquid for compressible gas flow тАФ the expansibility factor is required, and choked flow needs a different treatment entirely.
- Ignoring upstream straight run тАФ an elbow too close to the plate biases the reading regardless of how good the arithmetic is.
Examples
Frequently Asked Questions
Q = Cd ┬╖ E ┬╖ AтВА ┬╖ тИЪ(2╬ФP/╧Б), where Cd is the discharge coefficient, E = 1/тИЪ(1тИТ╬▓тБ┤) is the velocity-of-approach factor, AтВА is the bore area in m┬▓, ╬ФP is the differential in pascals and ╧Б is the density in kg/m┬│. For free discharge from a tank it simplifies to Q = Cd┬╖AтВА┬╖тИЪ(2gh).
Around 0.60 to 0.62 for a sharp-edged concentric plate in turbulent liquid flow. The exact value depends on the beta ratio, the Reynolds number and the tap arrangement, and for a metering installation it should come from the ISO 5167 correlation rather than a single assumed figure.
No. Part of the differential recovers downstream of the plate as the jet re-expands. The permanent, unrecovered loss is roughly (1 тИТ ╬▓^1.9) times the measured differential тАФ about 70% of it at ╬▓ = 0.5 тАФ and that is what costs pumping energy.
Use it to understand the method and get a first estimate, but a metering orifice must be designed and installed to ISO 5167 (or AGA 3 for gas), which specifies the plate geometry, tap locations, straight-run requirements and the coefficient correlation. The final bore and installation must follow that standard.