Conductivity to Resistivity Calculator
Convert between sigma and rho and find resistance from resistivity, step by step
Conductivity and Resistivity Are Reciprocals
Electrical conductivity and resistivity describe the same material property from opposite ends:
Symbols and SI units:
- â resistivity, ohm-metres (ÎĐ·m)
- â conductivity, siemens per metre (S/m); one siemens is one reciprocal ohm
There is no constant of proportionality and no unit juggling: is S/m. Copper at 20 °C sits at ÎĐ·m, so S/m.
Conductor metals are often quoted as a percentage of the International Annealed Copper Standard, .
The operating assumption: a homogeneous, isotropic material at a stated temperature. Both quantities drift with temperature, so a value without a temperature is incomplete.
Getting Resistance Out of Resistivity
Resistivity becomes a resistance once you add the geometry:
with in ohms, in metres and in square metres. The last form is how resistivity is measured in practice: take a sample of known length and cross-section, measure its resistance, and divide.
Temperature is handled with a linear coefficient about a reference temperature :
For copper, per °C referenced to 20 °C.
Watch the units people trip on. Water and process conductivity is quoted in ÂĩS/cm, not S/m; S/m ÂĩS/cm. Cable tables often use ÎĐ·mmÂē/m, where copper is â numerically the same as ÎĐ·m, because ÎĐ·mmÂē/m ÎĐ·m.
The mistake people make: measuring a two-wire loop and dividing by the one-way length. Use the full conductor length the current actually travels.
Common Mistakes to Avoid
- Inverting the wrong quantity â a small resistivity means a large conductivity. If gives , a reciprocal was skipped.
- Mixing ÂĩS/cm with S/m â divide ÂĩS/cm by to get S/m before inverting.
- Using mmÂē for in an SI formula â mmÂē is mÂē, a factor of a million.
- Ignoring temperature â a conductor running at °C has about more resistance than the same conductor at °C, which matters for voltage-drop work.
- Treating resistivity as a fixed constant for an alloy â it varies with composition, temper and impurity level, so use the supplier's figure for the actual material.
- Confusing resistivity with sheet resistance â sheet resistance is in ohms per square and applies to a thin film of thickness .
Examples
Frequently Asked Questions
Take the reciprocal: rho = 1/sigma. If sigma is in siemens per metre the answer comes out directly in ohm-metres, because one siemens is one reciprocal ohm. No extra constant is involved.
Measure its resistance R, its length L and its diameter, work out the cross-sectional area A = pi d squared / 4 in square metres, then use rho = RA/L. Quote the temperature with the result, since resistivity changes with it.
Use R = rho L / A, with the resistivity in ohm-metres, the length in metres and the area in square metres. Equivalently R = L/(sigma A) if you have the conductivity instead.
Divide by 10,000. Water quality instruments read in uS/cm, so 500 uS/cm is 0.05 S/m, which inverts to a resistivity of 20 ohm-metres. Convert first, then take the reciprocal.