PCB Trace Width Calculator
Trace width for a given current and temperature rise, plus microstrip impedance, step by step
The IPC-2221 Current Relation
Trace width for current is set by how much heating you will tolerate. The IPC-2221 chart fit is
Symbols and the units this empirical fit demands:
- — current, amperes (A)
- — allowable temperature rise above ambient, degrees Celsius (°C)
- — trace cross-sectional area, square mils (mil², where 1 mil = 0.001 in)
- — for an external (surface) trace, for an internal trace, which is buried and cannot shed heat as well
Width then comes from the copper thickness:
so 1 oz copper is mil (m) and 2 oz is mil.
The operating assumption: a bare trace in still air on a board that is not otherwise hot, carrying steady DC.
Impedance, and What the Formula Does Not Cover
For a controlled-impedance signal the width is set by geometry, not heating. The IPC-2141 microstrip approximation is
with in ohms, the dielectric height and , the trace width and thickness, all in the same length unit. FR-4 has at low frequency. A wider trace or a thinner dielectric gives lower impedance.
State this plainly: IPC-2221 is a conservative curve fit from the 1950s, not a thermal model of your board. It ignores adjacent copper pours, board material, via heating, altitude and airflow. IPC-2152 supersedes it with data that accounts for those effects and often permits narrower traces.
Use these results to understand and to sketch a first pass. The width that actually goes on a manufactured board must be confirmed against IPC-2152, your fabricator's stack-up and impedance data, and any product safety standard that governs spacing and creepage. A calculated number is not a released design.
Common Mistakes to Avoid
- Feeding millimetres into the IPC-2221 formula — it is an empirical fit in mils and square mils. Convert at the end: mil mm.
- Using the external for an inner layer — an internal trace needs and comes out roughly three times wider.
- Confusing area with width — the formula returns a cross-section in mil²; divide by the copper thickness to get width.
- Treating copper weight as a width — 1 oz describes thickness, mil, and says nothing about how wide the trace is.
- Forgetting plating — outer layers are usually plated up beyond the base foil weight, so the finished thickness differs from the stack-up nominal.
- Ignoring the return path — impedance depends on a continuous reference plane; a split under the trace invalidates the microstrip model.
- Sizing for average current on a pulsed load — heating follows the RMS value.
示例题目
常见问题
Use the IPC-2221 relation A = (I / (k x deltaT^0.44))^(1/0.725) with the area in square mils and k = 0.048 external or 0.024 internal, then divide the area by the copper thickness to get the width. One ounce of copper is 1.378 mil thick.
An inner layer is surrounded by dielectric and cannot lose heat by convection, so IPC-2221 halves the constant k from 0.048 to 0.024. For the same current and temperature rise that works out at roughly three times the cross-sectional area.
No. It is a conservative curve fit that ignores board material, copper pours, vias and airflow. Use it to get an initial number, then confirm the finished width against IPC-2152, the fabricator's capability and any product safety standard that applies to the board.
A wider trace lowers characteristic impedance and a thicker dielectric raises it. The IPC-2141 microstrip approximation captures the trend, but a controlled-impedance stack-up should always be confirmed by the fabricator against their actual materials.